Brand:
ACEYItem No.:
ACEY-BP24-200A300ACompliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1Payment:
T/TProduct Origin:
ChinaLead Time:
7days1-24 Series Bms Tester 200A Charge 300A Discharge Lithium Battery Protective Board Tester
Product Description
The battery protection board tester requires connection to a computer, the system generally requires XP system,the interface of tester and computer is RS232. The main test functions include overcharge protection, overcharge recovery, overdischarge protection, overdischarge recovery, overcurrent protection, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection time, balance current, balance voltage etc.
Parameter
1. Cycle: cycle times: 1 to 9999 times
2. Laboratory mode, can arbitrarily adjust the voltage value of a section
3 Can continuously provide charging and discharging current.
4. Using programming, the device carries out the number of cycles of each indicator of the protection board without interruption.
5. Log tracking, With log function, including the test of the entire process of operation records, abnormal records, can be used for the traceability of the test process.
6. Data processing, human-machine interface
7. Test data is saved in EXCEL file.
8. RS232 interface is used for the interface between the device and the host computer, which can ensure the stability and real-time data acquisition.
9. Accuracy calibration/software calibration
10. With sweeping code start function
11. MES system interface
12. Active equalization (can be customized)
13. Equalization current (customizable)
14. Communication protocol test (optional)
Test Functions
No. | Function | Range | Accuracy | unit |
1 | Self-consumption of single cell | 0--500 | ±0.1 | uA |
2 | Self-consumption | 0--5000 | ±1 | uA |
3 | Overcharge voltage | 500--5000 | ±1 | mV |
4 | Overcharge recovery voltage | 500--5000 | ±1 | mV |
5 | Overcharge voltage protection delay | 0--10000 | ±1 | mS |
6 | Overdischarge voltage | 500--5000 | ±1 | mV |
7 | Overdischarge recovery voltage | 500--5000 | ±1 | mV |
8 | Overdischarge voltage protection delay | 0--10000 | ±1 | mS |
9 | Overcharge protection current protection value | 0.1--200 | ±0.01 | A |
10 | Overcharge protection current protection delay | 0--20000 | ±1 | mS |
11 | Overdischarge protection current protection value | 0.1--300 | ±0.01 | A |
12 | Overdischarge protection current protection delay | 0.1--20000 | ±1 | mS |
13 | Equalization function | 500--5000 | ±1 | mV |
opening voltage | ||||
14 | Equalizing current | 1--500 | ±1 | mA |
15 | Charging current | 0.1--120 | ±0.01 | A |
16 | Discharging current | 0.1--120 | ±0.01 | A |
17 | Charging time | 0--100 | ±1 | S |
18 | Discharging time | 0--100 | ±1 | S |
19 | The difference of single cell self-consume | 0-500 | ±0.1 | uA |
20 | Resistance | 0-999 | ±1 | mΏ |
21 | Short circuit protection time | 0--5000 | ±1 | uS |
22 | The charging voltage of single cell | 500--5000 | ±1 | mV |
23 | The discharging voltage of single cell | 500--5000 | ±1 | mV |
24 | Open circuit voltage | 120000 | ±1 | mV |
25 | Number of voltage analogs | 24 | 0 | PCS |
Product Display