100V 30A battery life cycle tester mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.
Brand:
ACEYItem No.:
ACEY-HRCDS-100V30ACompliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1 SetPayment:
T/TProduct Origin:
ChinaLead Time:
7days100V 30A Battery Pack Life Cycle Tester With Energy-feedback
Application and Function
100V 30A battery pack life cycle tester is mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.
Equipment configuration list
No.
Category
Product name
Product model
Quantity
Remarks
1
Test equipment
Charge and discharge test equipment
ACEY-HRCDS-100V30A
18CH
2
Cabinet
Charging and discharging equipment cabinet
/
1PCS
Default without power input line
3
Computer
Computer
Dell computer I5-10500 processor / 16G memory /256G solid state + 1T hard disk /3 network port
1PCS
Optional, including mouse, keyboard and 19 inch AOC displayer
4
Accessories
Charge discharge test line
/
18PCS
Each channel has a set of test lines with a length of 3.5meters.(including fixture)
5
Accessories
Switch
TP-LINK TL-SF1008VE
1PCS
Single cabinet without switch
6
Accessories
Communication accessories
Communication line / Crystal head, etc.
Several
For communication
7
Accessories
USB Flash Drive
16G
1PCS
Contains Test software etc.
8
Accessories
File
/
1PCS
Test report, packing list, etc.
Advantages
Working Environment and Technical Parameters
Parameters
No. | Item | ACEY-HRCDS-100V30A | ||
1 | Main channels | 1CH/ module | ||
2 | Channel working mode | Completely independent | ||
3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV | ||
Discharge: CD, CP, CR | ||||
Still | ||||
Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
4 | Main channel Voltage | Single channel test range | 0V-100V | |
Min. discharge voltage | 6V | |||
Accuracy | ±0.05%FS+0.05%RD | |||
Resolution | 1mV | |||
Main channel Current | Single channel test range | ±30A | ||
Min. output current | 60mA | |||
Accuracy | ±0.05%FS+0.05%RD | |||
Resolution | 1mA | |||
Current start response time | <10ms(10%FS~90%FS) | |||
Time | Resolution | 1s | ||
Auxiliary voltage (Optional) | Range | DC:0-5V | ||
Accuracy | ±0.05%FS | |||
Resolution | 1mV | |||
Auxiliary temperature (Optional) | Range | ﹣20℃~100℃ | ||
Accuracy | ±1℃(0℃~80℃) | |||
Resolution | 0.1℃ | |||
Power | Output power | Single channel continuous working power 3000W. | ||
Stability | ±0.1%FS+0.1%RD | |||
5 | Communication | LAN | ||
Battery BMS communication | Support CAN 2.0A, CAN 2.0B; RS485 communication; | |||
Support DBC import, realize data reading with BMS CAN, and participate in process control | ||||
6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
Cycle time | Max. 9999 | |||
Programmable step | Max. 9999 | |||
Nested loop | Max. 10 layers | |||
Step time range | No limit, support h, min, s | |||
Data record | Time≥1s, Voltage≥0.1%FS, Current ≥0.1%FS | |||
Program feature | Each step has one or multiple exit. | |||
7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
Process list | Process number, working mode, process time, capacity, power, medium voltage, cut-off voltage, cut-off current, etc. | |||
Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
9 | Data saving | Save as files | ||
10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity | ||
Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc. | ||||
11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection | ||
Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection | |||
Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
12 | Barcode scan | Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system. | ||
13 | Sampling terminals | Four-polar sampling. Copper nose or other fixture. | ||
14 | Energy consumption | Discharge power feedback to grid | ||
15 | Cooling method | Forced Fan-cooled | ||
16 | Noise | Less than 70dB | ||
IP grade | IP20 | |||
17 | Repair | Modularized structure. Can be replaced or repair with spare parts. | ||
18 | Software update | Provide regular software upgrade services until the hardware is incompatible. |