ACEY-HRCDS-200V300A battery charge discharge test system is used for battery circle life testing, capacity testing, charging characteristic testing, discharging characteristic testing, charge retention capability testing, charge and discharge efficiency testing, over charge or over discharge rate affordability testing.
Brand:
ACEYItem No.:
ACEY-HRCDS-200V300ACompliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1 SetPayment:
T/TProduct Origin:
ChinaLead Time:
7days200V 300A Lithium Ion Battery Pack Charging And Discharging Machine
Application and Function
ACEY-HRCDS-200V300A battery charge discharge test system is used for charging and discharging tests for li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on to evaluate the performance of battery packs.
Equipment configuration list
No.
Category
Product name
Product model
Quantity
Remarks
1
Test equipment
Charge and discharge test equipment
ACEY-HRCDS-200V300A
3CHS
2
Cabinet
Charging and discharging equipment cabinet
/
1PC
Default without power input line
3
Computer
Computer
Dell computer I5-12500 processor / 16G memory / 256G solid state + 1T hard disk / 3 network port
1PC
Optional, including mouse, keyboard and21.5inch displayer
4
Accessories
Charge discharge test line
/
3PCS
Each channel has a set of test lines with a length of 3.5meters.(including fixture)
5
Accessories
BMS power supply
12V/24V
1
Optional, 2 channels for each power supply
6
Accessories
Switch
/
1PC
For software
communication use
7
Accessories
Communication accessories
Communication line / Crystal head, etc.
Several
For communication
8
Accessories
USB Flash Drive
16G
1PC
Contains Test software etc.
9
Accessories
File
/
1PC
Test report, packing list, etc
Working Environment and Technical Parameters
Parameters
No.
Item
ACEY-HRCDS-200V300A
1
Main channels
1CH/ module
2
Output power
The maximum power of channel operation is 60kW; timeless
3
Output power stability
±0.1%FS
4
Power quality at input side
Power factor
>99%(full load)
Total harmonic distortion rate
≤5%(full load)
5
Energy consumption parameters
Standard sine wave feedback energy, high efficiency (optimal efficiency 90%%)
6
Main channel working mode
Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV
Discharge: CD, CP, CR
Still
Working condition test; Pulse test.
BMS follow-up test, working condition test. Pulse test. DCIR test.
7
Main channel Voltage
Single channel test range
0.2V-200V, The intermediate value is continuously adjustable (wide test range, applicable to the test requirements of various battery modules)
Min. discharge voltage
12V(port voltage)
Accuracy
±0.05%FS
Resolution
1mV
Main channel Current
Single channel test range
±300A
Min. output current
200mA
Accuracy
±0.05%FS
Resolution
1mA
Current start response time
<5ms(10%~90%FS)
Time
Resolution
10ms
Auxiliary voltage (Optional)
Range
DC: 0-5V
Accuracy
±0.05%FS
Resolution
1mV
Auxiliary temperature (Optional)
Range
﹣20℃~100℃
Accuracy
±1℃(0℃~70℃)
Resolution
0.1℃
8
Communication
LAN
Battery BMS communication
Support CAN 2.0A, CAN 2.0B; RS485 communication
Support DBC import, realize data reading with BMS CAN, and participate in process control
9
Control program
Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online.
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, maximum temperature, minimum temperature, etc.
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature.
Cycle time
Max. 10000
Programmable step
Max. 10000
Nested loop
Max. 10 layers
Step time range
No limit, support h, min, s
Data record
Time≤10ms,Voltage≤0.1%FS, Current≤0.1%FS
Program feature
Each step has one or multiple exit
10
Working mode (Unit voltage and temperature are optional)
Constant current charging
Battery voltage, time, capacity, energy, temperature, cell voltage, cell voltage difference, RSOC cut-off.
Constant voltage charging
Current, time, capacity, energy, temperature, cell voltage, cell voltage difference, RSOC cut-off.
Constant current and constant voltage charging
Battery voltage, current, time, capacity, energy, temperature, cell voltage, cell voltage difference, RSOC cut-off.
Shelve
Deadline
Constant current discharge
Battery voltage, time, capacity, energy, temperature, cell voltage, cell voltage difference cut-off.
Constant power discharge
Battery voltage, current, time, capacity, energy, temperature, cell voltage, cell voltage difference cut-off.
Constant resistance discharge
Battery voltage, current, hour time, capacity, energy, temperature, cell voltage, cell voltage difference cut-off.
11
Data display(Unit voltage and temperature are optional)
Cycle list
Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc.
Process list
Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc.
Detail list
Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, monomer voltage l -- monomer voltage n, monomer voltage range etc.
12
Data export
Data can be exported as EXCEL, TXT or diagram. Provide data analysis curves and data lists in various ways, such as charge discharge curve, capacity decay rate, cycle life curve, charge discharge voltage, current, capacity, current time characteristics, etc
13
Data saving
Save as files
14
Curves type
X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity
Y-coordinate: total voltage, current, capacity, power, monomer voltage l-monomer voltage n, temperature 1-monomer temperature n, etc
15
Input protection
Overvoltage, overcurrent, phase loss, over temperature, protection alarm;
Output protection
Overvoltage, overcurrent, short circuit, capacity, temperature, single overvoltage and single undervoltage protection; No output when the battery voltage is not detected;
Power off protection
After external power failure, the battery and equipment are automatically disconnected, effectively avoiding accidents caused by re energization;
Hardware protection
Power off protection, open circuit protection and short circuit protection; Reverse connection of battery, wrong connection protection, overcurrent protection, overvoltage protection, overtemperature protection, hardware overvoltage, undervoltage and overcurrent protection;
Short circuit protection
External short circuit;
Software protection
Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection, equipment communication abnormal protection, auxiliary module communication abnormal protection;
Warning function
Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically.
16
Barcode scan
Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system.
17
Cooling method
Forced Fan-cooled
18
Sampling terminals
Four-polar sampling. Copper nose or other fixture.
19
Auxiliary channel acquisition line
The length of acquisition cable can be adjusted according to the actual situation
20
Noise
Less than 70dB
IP grade
IP20
21
Repair
Modularized structure. Can be replaced or repair with spare parts.
Product Display