ACEY-HP07SA is designed for 7 series battery packs for electric MVS, power tools and other products.Protection plate with strong carrying capacity, continuous discharge current up to 25A.
Brand:
ACEYItem No.:
ACEY-HP07SACompliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
Payment:
T/TProduct Origin:
ChinaLead Time:
7days3s 4s 6s 7s 15A BMS Battery Pcb Pcm For Lithium Battery Pack
Product Introduction
ACEY-HP07SA is designed for 7 series battery packs for electric MVS, power tools and other products.Suitable for different chemical properties of lithium cell, such as lithium ion, lithium polymer, lithium iron phosphate, etc.Protection plate with strong carrying capacity, continuous discharge current up to 25A.
● 3-7 cell series protection
● Various protection functions of charging and discharging
● Hardware discharge over current, short circuit protection function processing
● Reserve discharge control switch and discharge temperature protection position
● Very low static current consumption
Basic parameters
Battery pack structure: 7S
Charging mode: CC-CV(constant current constant voltage)
Discharging mode: Constant current constant voltage
Output terminal: C-
Input terminal: B-,BC0-BC7
Electrical Characteristics (The test needs to be carried out in a room with a temperature of 25±2°C and a relative humidity of 65 +/- 20 %)
Functions | Test items | specification | Unit | ||
Min. | Type | Max. | |||
Operating Voltage | voltage range | 19.6 | 29.75 | V | |
Operating current | Recharging current | -- | 10 | 15 | A |
Discharging current | -- | 10 | 15 | A | |
Charging protection | Charger voltage (CC-CV) | 29.4 | V | ||
Over-charge protection voltage | 4.22 | 4.25 | 4.28 | V | |
Over-charge protection delay time | 500 | 1000 | 1500 | mS | |
Over-charge protection recovery voltage | 4.14 | 4.19 | 4.23 | V | |
Equalization function | Balanced turn-on voltage | V | |||
Equilibrium current | mA | ||||
Discharge protection | Over-discharge protection voltage | 2.72 | 2.8 | 2.88 | V |
Over-discharge protection delay time | 50 | 100 | 200 | mS | |
Over-discharge protection recovery voltage | 2.8 | 2.9 | 3 | V | |
Over-discharge protection recovery condition | Disconnected the load | ||||
Overcurrent protection | Charging overcurrent protection value | / | A | ||
Overcurrent charge delay | / | mS | |||
Charging release adjustment | / | ||||
Discharge overcurrent 1 protection current value | 70 | 80 | 90 | A | |
Discharge overcurrent 1 protection delay | 50 | 200 | mS | ||
Discharge overcurrent protection recovery condition | Disconnect the load | ||||
Short circuit protection | Short circuit protection current | - | - | - | A |
Short circuit protection delay time | 100 | 200 | 300 | uS | |
Short circuit protection recovery | Disconnect the load | ||||
Temperature protection | Temperature protection value | / | ℃ | ||
( Internal) | |||||
Internal resistance | Discharge loop internal resistance | / | 10 | 20 | mR |
Self-consuming | Operating mode | / | 20 | 50 | uA |
Operating temperature | Normal working range | -20 | 70 | ℃ | |
storage temperature | Humidity is lower than 90% | -40 | 85 | ℃ | |
Protection board size | Length*Width*Height | 66*34*10 | mm | ||
Product Display