ACEY-BIT60-30A300A battery comprehensive tester is suitable for all lithium-ion battery packs with CH+P+CH - P - ports to test various comprehensive performance parameters of the battery pack.
Brand:
ACEYItem No.:
ACEY-BIT60-30A300ACompliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1setPayment:
T/TProduct Origin:
ChinaLead Time:
7days
60V 30A Charge 300A Discharge Lithium Ion Battery Pack Comprehensive Tester
Description
Lithium battery integrated tester is used to test the various comprehensive performance parameters of finished battery packs. The main test items include open circuit voltage, AC internal resistance, continuous charging current, continuous charging voltage, continuous discharging current, continuous discharging voltage, charging overcurrent protection current, discharging overcurrent protection current, short-circuit protection time, overcurrent delay time and post-test voltage etc.
Testing items
1.Voltage: No-load voltage and Short circuit protection voltage after the test is completed,Range:0-60V。
2.Internal Resistance:ACIR1000hz, Range:0-4000mΩ
3.Charging overcurrent protection current , Range:0-30A。
4.Continuous charging current, Range:0-30A。
5.Continuous charging voltage monitoring, Range:0-60V。
6.6-1Discharge overcurrent protection current and delay tim, Rang of current:0-300A,Overcurrent maximum power 18KW. 6-2 Overcurrent test mode: (1) Step test (2) quick test.
7.Continuous discharge current, Range::0-300A
8.Continuous discharge voltage judgment, Range: 0-60V
9.Short circuit protection time:≤1000μS, Max Short circuit current about 5000A
10.Single cell voltage monitoring
11.Appreciation of charge and discharge voltage:
12.During the working test, if the power supply is cut off and the MOS tube of the protection board is turned off, no inrush current will be generated, and the protection board of the lithium battery pack will not be damaged.
13.Support MES system
14.Database: The software comes with a database, which can generate excel tables.
15.Step-by-step mode: the test sequence can be adjusted automatically.
16.Support chassis expansion.
Technical Parameters
1)Voltage range: 0-60V resolution:1mV Accuracy 0.1%RD+0.1FS
2)Internal resistance: 0-2000mΩ resolution:0.001mΩ Accuracy 0.1%RD+0.1FS
3)Charge current: 0-30A resolution: 0.001A Accuracy 0.1%RD+0.1FS
4)Discharge current: 0-300A at the highest voltage, continued discharge current 300A,resolution:0.001A Accuracy 0.1%RD+0.1FS
5)Overcurrent delay time: 0-30S resolution:1mS Accuracy 0.1%RD+0.1FS
6)short circuit time: 0-2000μS resolution:1μS Accuracy 0.1%RD+0.1FS
7)NTC range: 0-100K 0.001K
8)R1 range: 0-100K 0.001K
9)Power supply: AC 200V-240V
10)Maximum working power for charging:1800W(When charging with maximum current)
11)Maximum working power for discharging:18KW(When discharging with maximum current
12)surge voltage<15V
Product Details