ACEY-BA10060-6 regenerative battery pack test system is mainly used for ternary, lithium iron phosphate, lead-acid, nickel-metal hydride nickel-cadmium and other battery pack aging test.
Brand:
ACEYItem No.:
ACEY-BA10060-6Compliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1 SetPayment:
T/TProduct Origin:
ChinaLead Time:
7days100V 60A Charge 60A Discharge Regenerative Battery Aging Machine
Product Description
The regenerative battery pack test system is designed for a comprehensive range of battery pack aging tests, suitable for various types including ternary, lithium iron phosphate, lead-acid, nickel-metal hydride, and nickel-cadmium. It can be utilized for both same port and sub-port battery packs, with a voltage range of 12V to 100V and adjustable charging and discharging current from 100mA to 60A. The equipment is ideal for battery manufacturing enterprises to test battery modules during production, as well as for high current charging and discharging detection in EV/HEV power battery systems. It is also used for high-current charging and discharging tests, battery performance assessments, and daily maintenance of battery modules in battery factories and charging stations.
Functions
Advantages
1. Voltage and current accuracy ± (0.1%RD+0.1%FS), data recording time 5S/time, high stability.
2. Can be set for independent charging and discharging conditions after free grouping for each channel.
3. complete input and output, software and hardware protection, reverse connection protection, power failure renewal, short circuit protection, etc.
4. Channel start without inrush current, constant current to constant voltage seamlessly over, without any current surges
5. Network integrated management, a computer centralized control, support remote monitoring
6. Modular design of power unit, easy to produce, easy to maintain
7. Clear and comprehensive data, real-time monitoring and uploading to MES system
Parameters
NO |
Item |
Function requirement |
||
1 |
Channel |
6 |
||
2 |
Action Mode |
Completely independent |
||
3 |
Main channel work mode |
Charging: constant current and constant voltage charging CCCV.&CC Discharge: constant current discharge CD.& CP Resting, stopping |
||
Main channel test abort condition |
Time, voltage, current, capacity, etc |
|||
4 |
Voltage of main channel |
Votage range of Charge&discharge |
12V-100V |
|
Accuracy |
±(0.1%RD+0.1%FS) |
|||
Resolution |
1mV |
|||
Current of main channel |
Maximum output current |
Discharge & Charge 60A |
||
Minimum output current |
100mA |
|||
Accuracy |
±(0.1%RD+0.1%FS) |
|||
Resolution |
1mA |
|||
Power |
Output |
Single channel continuous operation maximum power 0.6KW |
||
Auxiliary channel parameter cut-off function |
The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. |
|||
5 |
Control program |
Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. |
||
Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend。 |
||||
Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. |
||||
Cycle times |
Max 9999 |
|||
Work step time unit |
h、min、s are available |
|||
Data logging |
Min 5S |
|||
6 |
Data display method |
Loop List |
cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. |
|
Process List |
process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. |
|||
|
Detailed list |
There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. |
||
7 |
Data export method |
The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. |
||
8 |
Curve Type |
X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. |
||
Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. |
||||
9 |
Software protection |
Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. |
||
Hardware protection |
Battery reversal, over-current protection, over-voltage protection, short-circuit protection. |
|||
Alarm function |
The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. |
|||
10 |
Output wire |
Four-wire connection mode with separate current and voltage lines. |
||
11 |
Maintainability |
Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. |
||
12 |
Test channel and battery pack connection method |
Alligator clamp |
||
13 |
Equipment testing environment and technical requirements |
Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant Working environment: temperature -10℃~40℃ / humidity: 10%~90% |