ACEY-BA3020-18 battery pack cycle tester is applicable to the aging test of battery packs such as ternary, lithium iron phosphate, lead acid, nickel-hydrogen nickel-cadmium, etc.
Brand:
ACEYItem No.:
ACEY-BA3020-18Compliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1 SetPayment:
T/TProduct Origin:
ChinaLead Time:
7days30V 20A Regenerative Battery Pack Charge Discharge Test Equipment For Ni-MH Lead Acid Lithium Battery
Application
Functions
Advantages
1.Equipment accuracy (0.1%RD +0.1%FS), high stability;
2.Independent charging and discharging conditions can be set after free grouping for each channel;
3.Complete input and output, software and hardware protection, reverse connection protection, power-off connection protection and other functions;
4.Channel start without impact current, constant current to constant voltage seamless transition, without any current surge;
5.Network integrated management, a computer centralized control, support remote monitoring;
6.Modular design concept, box plug-in design, easy to maintain;
7.Clear and comprehensive data, real-time monitoring and uploading MES system;
8.The cabinet can be extended.
Parameters
No. | Project | Functional Requirements | ||
1 | Number of cabinet channels | 18 channels | ||
2 | Channel action mode | Completely independent | ||
3 | Main channel operating mode | Charging: constant current CC, constant current constant voltage charging CCCV; Discharge: constant current discharge CD, constant power CP; | ||
Let it stand and stop. | ||||
Main Channel Test Stop Conditions | Time, voltage, current, capacity, etc. | |||
4 | Main channel voltage | Charging voltage range | 5V ~ 30V | |
Discharge voltage range | 5V ~ 30V | |||
Accuracy | ±(0.1%RD+0.1%FS) | |||
Resolution | 1mV | |||
Main channel current | Maximum output current | Charge current 20A, discharge current 20A, | ||
Minimum output current | 100mA | |||
Accuracy | ±(0.1%RD+0.1%FS) | |||
Resolution | 1mA | |||
Power | Output power | Single channel continuous operation maximum power 600W | ||
Auxiliary channel parameter cutoff function | You can set the main channel step to stop or switch when the auxiliary channel signal reaches a certain condition. | |||
5 | Control Procedure | 1. Support data protection due to power failure, manual stop and connection from data files | ||
Continued testing. | ||||
Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, | ||||
Current upper limit, voltage and current trend. | ||||
The auxiliary channel protection conditions can be set, and the parameters can be set include: upper voltage limit, lower voltage | ||||
Limit, upper temperature limit, lower temperature limit. | ||||
Number of cycles | Maximum 9999 | |||
Step time unit | Support h, min, s format | |||
Data upload interval | Minimum 5S | |||
6 | Data Display Mode | Cycle List | There are cycle number, charge/discharge capacity, charge/discharge efficiency, Charge/discharge energy, charge/discharge average voltage, etc. | |
Process List | There are process serial number, working mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
Detail List | There are record serial numbers, system time, cumulative time, voltage, Current, energy, power, etc. | |||
7 | Data Export Method | The data can be exported into EXCEL and chart files, which can provide a variety of data analysis curves such as charge and discharge efficiency, charge and discharge curves, voltage, capacity, current time characteristics, etc. | ||
line into EXCEL. |