Prismatic Battery Formation And Grading System is mainly used for power battery capacity separation, capacity testing and Cycle life testing, and is the mainstream in the field of power battery testing equipment to meet the needs of power battery.
Brand:
ACEYItem No.:
ACEY-5100-48Compliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1Payment:
T/TProduct Origin:
ChinaLead Time:
7days48 Channels 100A Energy Feedback Prismatic Battery Formation and Grading System
Product Description:
Battery Cell Formation and Grading System is mainly composed of computer, communication interface and battery testing cabinet. Battery testing cabinet consists of a jig and a board body for placing the jig, constant current and constant voltage source, sampling circuit, dividing capacity control circuit, microcontroller and control panel. It is mainly used for power battery capacity separation, capacity testing and Cycle life testing, and is the mainstream in the field of power battery testing equipment to meet the needs of power battery.
Equipment Features and Appearance Structure
System Features:
●Single point independent, independent constant current and constant voltage source, stable without impact. Functions such as start, stop, pause, resume and protection can be realized.
●The equipment accuracy is 0.05%, the data recording time is 1 second/time, and the stability is high.
●The software has powerful functions and friendly man-machine interface.
●Four-wire test interface to ensure high measurement accuracy. Modular design concept, easy to maintain.
Equipment Structure:
1.Independent CPU board, double keyboard board, unified sending control of the whole cabinet;
2.8-channel constant current and constant voltage control module;
3.Bidirectional AC/DC inverter module;
4.Tray-type automatic clamping and clamping (cylinder) mode.
System structure and working principle
System Composition
1.Lithium battery is converted into capacity equipment.
2.Computer with USB interface (bring your own).
3.USB to 485 interface converter or five types of communication lines and crystal heads.
4.Battery scanning system.
5.ACEY product software.
Specification:
Equipment structure |
|
Number of Device Channels |
The whole machine has 48 channels |
Exterior dimension |
Width 1009mm × Length 800mm × Height 1843mm |
Chassis Color |
Standard gray black (customizable)) |
Fixture form |
Power battery flat head clamp |
Clamp spacing |
81mm |
Support battery specifications |
Battery compatible Length 90-220mm; Thickness 15-70mm; Height 80-230mm; Battery |
Ear 60-150mm |
|
Channel Control Mode |
Each battery has a completely independent constant current constant voltage source, stable and no impact. Realizable start |
move, stop, pause, continue and protect |
|
Each channel has an independent constant voltage, constant current hardware control circuit |
|
Each channel charging current, discharge current accuracy can be automatically calibrated by software |
|
Working power supply |
Three-phase 5 wire system AC380V ± 10%,50HZ |
power factor |
≥ 0.99 |
AC current distortion rate |
≤ 2% |
Power Department Efficiency Index |
Charging ≥ 80%, discharging ≥ 75% |
Working power consumption |
≤ 29KW |
equipment failure rate |
<1% |
Working environment |
Temperature -10~40, relative humidity 80% |
Heat dissipation mode |
Natural air intake, upward exhaust |
smoke alarm |
Optional |
Power component protection function |
1. Grid voltage overrun protection |
2. Power grid frequency overrun protection |
|
Channel Parameters |
|
Voltage measurement range |
DC 0~5V |
Battery voltage range |
Charge DC 0~4.5V; Discharge DC 4.5~1.5V |
Constant voltage range |
DC 2~4.5V |
Voltage accuracy |
±(0.5 reading ‰ +0.5 ‰ full) |
Voltage control resolution |
0.1mV |
Voltage sampling resolution |
0.1mV |
voltage stability |
≤(± 1mV) |
Current range |
Charging DC 200mA ~ 100A; Discharging DC 200mA ~ 100A |
Current accuracy |
±(0.5 reading ‰ +0.5 ‰ full) |
Current control resolution |
1mA |
Current Sampling Resolution |
0.1mA |
Current stability |
≤(± 1mA) |
Current rise time (90% load) |
≤ 50MS |
Channel startup time (90% load) |
≤ 50MS |
Software function |
|
Control mode |
Computer-controlled equipment work, full cabinet control, with scanning system |
Communication mode |
485 serial port communication (baud rate 57600 )/ TCP communication |
Process Settings |
Up to 32 steps and 256 cycles can be set |
Charging mode |
Constant current, constant voltage, constant current and constant voltage |
Charging end conditions |
Voltage, current, time, capacity,-△V |
Discharge mode |
Constant current, constant power, constant resistance |
Product Details: