Prismatic Cell Discharge Tester adopts high-precision measurement technology, which can accurately measure the voltage, current, power, capacity, internal resistance, and other parameters of the battery pack to ensure the accuracy and reliability of the test results.
Different channels can be customized according to customer requirements, and the current and voltage are unified, its suitable for mass production.
Brand:
ACEYItem No.:
ACEY-BCTCompliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1 SetProduct Origin:
ChinaLead Time:
7days64 Channels 5V 20A Prismatic Battery Cell Charge Discharge Capacity Tester
Description
Prismatic cell charge and discharge tester is an instrument used to test the charging and discharging performance of square batteries. It can measure battery capacity, internal resistance, open circuit voltage, charging efficiency, discharging efficiency, cycle life, and other indicators, making it an essential device for battery research, production, testing, and quality control.
Features
1. Each channel can be started and stopped at a single point, and the response speed is fast.
2. The operation is simple, convenient and intuitive.
3. Modular design, easy to maintain..
4. The digital current and voltage automatic calibration function.
5. Using network connection and SQL database.
6. The hardware technology is advanced, stable and durable.
Specification
Working power
Three-phase five-wire system AC380V±10%, 50HZ
Work environment
Temperature 0-40 degrees, relative humidity ≤80%
Heat dissipation
to enter the air naturally and exhaust the air upward
Overall energy saving
Channel Parameter
Voltage measuring range
0-5V, 1MV resolution
Battery voltage range
Charge 0-4.5V: Discharge 4.5-2V
Constant voltage range
2.5V-4.5V
voltage accuracy
±(1‰ reading +1‰ full)
Current accuracy
±(1‰ reading +1‰ full)
Software Function
Control mode
Computer connection equipment work, FCL control
Communication mode
RS485 baud rate 57,600
Process set
A maximum of 32 work steps and 256 cycles are se
Charging mode
Constant current, constant pressure
Charging cutoff condition
Voltage, current, time, capacity
Discharge
constant current
Discharge cut-off condition
Voltage, time, capacity
Defensive function
Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc
Time range
Set it anywhere from 0 to 30,000 minutes
Time accuracy
≤±1‰
Sampling inspection period
≤3S
Minimum frequency of data recording
≤5S
Battery sorting
By capacity, time, discharge platform, etc
Data processing
Data, graphs, and loop diagrams
over 70%
Product Details