Brand:
ACEYItem No.:
ACEY-BCT520-256HCompliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1 SetPayment:
T/TProduct Origin:
ChinaLead Time:
7days5V 10A 20A Cylindrical Battery Cell Capacity Grading Testing Equipment
Product Description
This regenerative battery cell testing machine is used to test the capacity of cylindrical batteries through cyclic charging and discharging tests. The whole machine has 256 channels and can test 256 cells simultaneously. It uses a customized battery cell holder for cylindrical batteries with diameters from 32 to 60 mm and lengths from 90 to 165 mm. And with energy-saving function.
System Features
Equipment Structure
Main technical parameters
Number of equipment channels
The whole machine has 256chs
External dimension
Length 1684* width 1091* height 1640
Case color
Standard gray / black (customizable)
Clamp type
Flat head clamp (optional with crocodile clamp)
Clamp spring
37MM
Support battery specifications
Diameter range: 32-60MM, length range: 90-165MM
Channel control mode
Each channel can be started, stopped, suspended, continued and protected independently.
Each channel has independent constant voltage and current. Hardware control circuit
The accuracy of charging current and discharging current of each channel can be calibrated automatically by software
Working power supply
Three phase five wire AC380V土10%, 50Hz
Power factor
≥0.99
AC current distortion rate
≤2%
efficiency of the whole machine
Charge 80%, discharge 70%
Power consumption work
≤ 15.5KW
Equipment failure rate
<1%
Work environment
Temperature -10~40°C. Relative humidity 80%
Heat dissipation mode
Natural wind in, upward exhaust
Voltage measurement range
DC 0~5V
Battery voltage range
Charge DC 0~4.5V; discharge DC 4.5~2V
Constant voltage range
DC 2~4.5V
Voltage accuracy
±(0.05% reading + 0.05% full), resolution ratio 1mV
Voltage stability
≤(±1mV)
Current range
Charge DC 200mA~20A; Discharge DC 200mA~20A
Current accuracy
±(0.05% reading + 0.05% full), resolution ratio 1mV
Current stability
≤(±1mA)
Control mode
Computer control, can control the whole cabinet with scanning function
Communication mode
485s port communication (port rate 57600)/ TCP
Process settings
Up to 32 steps and 256 cycles can be set
Charging mode
Constant current; constant pressure; constant current & pressure
Charging cut-off conditions
Voltage, current, time, capacity
Discharge mode
Permanent flow, constant power, constant resistance
Discharging cut-off conditions
Voltage, time, and capacity
Protection function
Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power off protection, data breakpoint recovery
Time frame
0~3000 min / step in min
Time accuracy
≤±0.1%
Sampling inspection cycle
1s-60s optional
Battery sorting
Divide according to capacity, time, open-circuit voltage, discharge platform, etc.
Data processing
Can record voltage, current, time, capacity etc, automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage, provide data curve and cycle diagram; can output text, excel, word or mdb format data file
Basic function of software
1. The software supports various connections, such as manual pause continuation, software shutdown continuation, power outage, disconnection in equipment communication, abnormal stop continuation;
2. Support bar code scanning, scanning one-dimensional code, QR code, channel jump scanning, loading scanning and other scanning methods;
3. Local test detailed data storage, can view the current test data and historical data of each channel at any time, have data and curve corresponding two ways, and support excel report in single or batch form, and can set the test end automatic data export according to the need.
4. Support capacity sorting, and grade the battery sorting;
5. Support the qualified judgment after the test, and judge the pass / ng results according to the specified cycle capacity, voltage, time and other information;
6. Support various step protection and global voltage, current, temperature abnormal protection, and abnormal alarm, support battery pack overcharge, overdischarge protection test;
7. Support channel parallel (according to equipment);
8. Support unit conversion;
9. Support database server background storage or MES docking;
10. Software offline protection;
Product Details